Conductors: Silver-plated copper with 40 microinches minimum coating thickness per ASTM B-298. Also available on special order are constructions with nickel-plated copper, silver-plated or nickel-plated, high-strength high-conductivity copper alloy.
Insulation: Extruded PTFE, nominal wall .010 (0.25mm). Bondable treated or sodium-etched coating can be supplied upon request.
Color Coding: Insulation color coding to MIL-STD-104 is available in solid colors and stripes.

Temperature Range: -55C to +200C with silver-plated conductors. -55C to +260C with nickel-plated conductors.
Insul. Flaw Test (Spark Test): 4,600 Volts rms @ 3.0 kHz.
Min. Insul. Resist.: Meets specification requirements.
Heat Resistance: +290C for 96 hours.
Voltage Rating: 600 Volts rms.
|

This wire insulated with PTFE is rated at 600 volts rms, with the corresponding DC potential at 1,500 volts. Suitable for high-frequency use at elevated temperatures in high-reliability programs where electrical and thermal stability are importan

Passes VW-1 Vertical Flame Test. OHSA Acceptable. MIL-W-16878/4 (previously Type 'E').
|